{"product_id":"h-type-sealed-quartz-optical-electrochemical-cell","title":"H-Type Sealed Quartz Optical Electrochemical Cell","description":"\u003cdiv data-page-id=\"TRhrdBC3VofITtxK4F3c8ZsDnKd\" data-lark-html-role=\"root\" data-docx-has-block-data=\"true\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-RctedxHOCoO2T6xfeUZcqIlcn3b\"\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-HSqddp1WXoDE5bxgqIpcDEQtnnd\"\u003eThe \u003cstrong\u003eFrankLab H-Type Sealed \u003c\/strong\u003e\u003cstrong\u003eQuartz\u003c\/strong\u003e\u003cstrong\u003e Optical Electrochemical Cell\u003c\/strong\u003e is a dual-compartment, optically accessible electrochemical reactor designed for \u003cstrong\u003espectroelectrochemistry\u003c\/strong\u003e and \u003cstrong\u003ephoto-electrochemical studies\u003c\/strong\u003e. This high-performance cell allows for \u003cstrong\u003ein-situ measurements\u003c\/strong\u003e using UV-Vis, Raman, and IR spectroscopy, ideal for \u003cstrong\u003eoperando spectroscopy experiments\u003c\/strong\u003e. The \u003cstrong\u003esingle-layer configuration\u003c\/strong\u003e of this cell offers \u003cstrong\u003e125 mL capacity per chamber\u003c\/strong\u003e and is designed for applications such as \u003cstrong\u003eCO₂ reduction reactions (CO₂RR)\u003c\/strong\u003e, \u003cstrong\u003ephoto-electrochemical water splitting\u003c\/strong\u003e, and \u003cstrong\u003emembrane-separated electrocatalysis\u003c\/strong\u003e.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-O0nsdZvHhoZIUxxhx6uchySSnod\"\u003eThe \u003cstrong\u003eH-type\u003c\/strong\u003e design enables \u003cstrong\u003eseparate half-reactions\u003c\/strong\u003e with independent \u003cstrong\u003egas control\u003c\/strong\u003e for each chamber, minimizing product crossover and ensuring high-quality data collection.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-YBgedKUR0o8xLwxQH5jcrVNtneb\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-BEhgd3jYRosZPwxLwYBc2ZAhnqc\"\u003e•\u003cstrong\u003eSingle-Layer Configuration\u003c\/strong\u003e:\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Rkypd1MlwooOckxtayCceY2enTh\"\u003e\u003cstrong\u003e125 mL per chamber\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-ODsTdDUr3oqaoPxOXzrcJbVhnQf\"\u003eIdeal for \u003cstrong\u003ebasic electrochemical reactions\u003c\/strong\u003e that require optical access for in-situ spectroscopic measurements.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-TUsBdoVDQoHIm5xpshvcLTcanwd\"\u003e•\u003cstrong\u003eOptical Access\u003c\/strong\u003e:\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-BJeNd9d5xoNee7xe4tUcZD71nmh\"\u003e\n\u003cstrong\u003eIntegrated glass optical port\u003c\/strong\u003e for \u003cstrong\u003eUV-Vis\u003c\/strong\u003e, \u003cstrong\u003eRaman\u003c\/strong\u003e, and \u003cstrong\u003eIR\u003c\/strong\u003e spectroscopy measurements in the reaction zone without disturbing the electrochemical setup.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-IE6xdE6aYozWBExmlRAc32NlnJg\"\u003e•\u003cstrong\u003eIndependent Gas Control\u003c\/strong\u003e:\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Nu1hde4IpoTnY8x3d2QcZtxynFg\"\u003e\n\u003cstrong\u003eGas inlet and outlet\u003c\/strong\u003e per chamber for \u003cstrong\u003eCO₂\u003c\/strong\u003e, \u003cstrong\u003eN₂\u003c\/strong\u003e, \u003cstrong\u003eO₂\u003c\/strong\u003e, or \u003cstrong\u003eAr\u003c\/strong\u003e purging.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-MhtcdfoHaoBEpUxFu6oc9VTCnRe\"\u003eAllows for \u003cstrong\u003eindependent gas purging\u003c\/strong\u003e and controlled environments for each half-reaction.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-MTBcdBiXBo1MrDxyPu9cyoMnn60\"\u003e•\u003cstrong\u003eModular Electrodes\u003c\/strong\u003e:\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-WKpYdXgXHoPDwFx0eakcpoGTnCb\"\u003eCompatible with a variety of electrodes, including \u003cstrong\u003eglassy carbon\u003c\/strong\u003e, \u003cstrong\u003eplatinum\u003c\/strong\u003e, \u003cstrong\u003egold\u003c\/strong\u003e, and \u003cstrong\u003eAg\/\u003c\/strong\u003e\u003cstrong\u003eAgCl\u003c\/strong\u003e reference electrodes.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Mty8daxBJoE5DZxVgdLcSpILnc2\"\u003eCustom options available for \u003cstrong\u003eoptical thin-layer electrodes\u003c\/strong\u003e.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-DFWkdfbYUo6jZQxxq1ec9QPJnFc\"\u003e•\u003cstrong\u003eMembrane\u003c\/strong\u003e\u003cstrong\u003e Interface\u003c\/strong\u003e:\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-JSxedS27hoTgwAxAL5qcRrSnnLb\"\u003e•\u003cstrong\u003eFlat \u003c\/strong\u003e\u003cstrong\u003emembrane\u003c\/strong\u003e\u003cstrong\u003e clamping zone\u003c\/strong\u003e suitable for \u003cstrong\u003eNafion\u003c\/strong\u003e, \u003cstrong\u003eAEM\u003c\/strong\u003e, or \u003cstrong\u003eCEM\u003c\/strong\u003e membranes.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-NjXAdcXIhoVERTxt4JhcIl7enRb\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-ZcmydfYqXoPWyrxumYQcBufmnkg\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv data-type=\"sheet\" class=\"old-record-id-QVOFdyFhLo0MXtxUfFycblkNnPd\"\u003e\n\u003cmeta content=\"text\/html; charset=utf-8\" http-equiv=\"Content-Type\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"192\"\u003e\n\u003ccol width=\"222\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eParameter\u003c\/td\u003e\n\u003ctd\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"46\"\u003e\n\u003ctd\u003eCell Type\u003c\/td\u003e\n\u003ctd\u003eH-type sealed optical electrochemical cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eAvailable Volume\u003c\/td\u003e\n\u003ctd\u003e125 mL per chamber (2 chambers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003eHigh-purity quartz glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"46\"\u003e\n\u003ctd\u003eOptical Window\u003c\/td\u003e\n\u003ctd\u003eIntegrated glass optical port (quartz optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"46\"\u003e\n\u003ctd\u003eSealing Method\u003c\/td\u003e\n\u003ctd\u003ePTFE threaded caps + chemical-resistant O-rings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"46\"\u003e\n\u003ctd\u003eGas Ports\u003c\/td\u003e\n\u003ctd\u003eIndependent gas inlet + outlet (per chamber)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eElectrode Ports\u003c\/td\u003e\n\u003ctd\u003eWorking \/ counter \/ reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"46\"\u003e\n\u003ctd\u003eMembrane Interface\u003c\/td\u003e\n\u003ctd\u003eFlat membrane clamping zone (Nafion \/ AEM \/ CEM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e−20 °C to 120 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"46\"\u003e\n\u003ctd\u003ePressure\u003c\/td\u003e\n\u003ctd\u003eAtmospheric \/ low-pressure operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eChamber Configuration\u003c\/td\u003e\n\u003ctd\u003eSingle-layer, two chambers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-NtRodXlLIokJrFxA69hcnqXdnsh\"\u003e\u003cstrong\u003eHow to Use\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-AAQldSkbgoct0hxeJHichx6Gngb\"\u003e\n\u003cstrong\u003e1.Handling \u0026amp; Assembly\u003c\/strong\u003e:\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-SCdgdoa8OogpIOxNEbwc79VRn6f\"\u003e•\u003cstrong\u003eWear gloves\u003c\/strong\u003e to avoid contamination.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-UWDedkBeZoSp0JxA8sWcIcWMn3e\"\u003e•\u003cstrong\u003eUse sharp blades\u003c\/strong\u003e or \u003cstrong\u003elaser cutting\u003c\/strong\u003e to cut the materials to prevent fiber damage.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Qef7dnvdSoNXlQxYMO8cgBtDnzh\"\u003e\n\u003cstrong\u003e2.Electrochemical Setup\u003c\/strong\u003e:\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-OTmAdQvbeoPtV3xPEf3cbLNAnme\"\u003e•Ensure \u003cstrong\u003eproper sealing\u003c\/strong\u003e between the carbon paper and the catalyst layer to reduce contact resistance.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-P5ind5SXKoFtjbxXmddcbuW8nob\"\u003e\n\u003cstrong\u003eCalibrate\u003c\/strong\u003e for \u003cstrong\u003egas purging\u003c\/strong\u003e and \u003cstrong\u003eoptical measurements\u003c\/strong\u003e before starting experiments.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-OomUdRCp4oWYBfx7XxScv2winoe\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-NbBid69BKoo4WMxskuRczn9en8d\"\u003e\u003cstrong\u003eStorage \u0026amp; Transportation\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-SriQdaUhAoJBRuxFiBhcM5clnhf\"\u003e\n\u003cstrong\u003e1.Storage Conditions\u003c\/strong\u003e:\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-IpyCdbvc0oGKIHxueIBcn5qhncf\"\u003e•Store in a \u003cstrong\u003edry, dust-free\u003c\/strong\u003e environment.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-WKhed9pEvok3VoxNG8qcFGHunsR\"\u003e•\u003cstrong\u003eTemperature\u003c\/strong\u003e: 5°C–30°C, \u003cstrong\u003eRelative Humidity\u003c\/strong\u003e: \u0026lt;60%.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Bi4VdPQtvoTdsqx91B9c6kZUndh\"\u003e\n\u003cstrong\u003e2.Handling\u003c\/strong\u003e:\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-JYN9dGlCdoQDwAxCUQ4cavqunrd\"\u003e•Avoid \u003cstrong\u003epressure\u003c\/strong\u003e, \u003cstrong\u003efolding\u003c\/strong\u003e, or \u003cstrong\u003erolling\u003c\/strong\u003e to prevent damage.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-GgUUdBDRjogrZKxztxYca2C1nnc\"\u003e•\u003cstrong\u003eRe-seal unused carbon paper\u003c\/strong\u003e in its original packaging to preserve its quality.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-A5lNd8jNXovmEwxqhXPcLDaznzf\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-S1uSd6IJgoirNTxjUshc9lmNnIg\"\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-HFC1dlqIko5mwvxO2iWc0MpCnAg\"\u003e•\u003cstrong\u003eCO₂ Reduction Reaction (CO₂RR)\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-NRyOdL8Dnom839xfjuicK7tonOb\"\u003e•\u003cstrong\u003ePhoto-electrochemical (PEC) Water Splitting\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-CxN6d6O7IofbHdxvuX4cBk13nGd\"\u003e•\u003cstrong\u003eSpectroelectrochemistry\u003c\/strong\u003e (UV-Vis, Raman, IR)\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Q86Ndq18sov22VxCHrScxNErnJd\"\u003e•\u003cstrong\u003eMembrane-Separated Electrocatalysis\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-ViPvd3C4von7X7xQcYecVnoYnhr\"\u003e•\u003cstrong\u003eGas-Liquid Electrochemical Interfaces\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-FHDcd716soApCpxQEfecZHmznJe\"\u003e•\u003cstrong\u003eMechanistic \u0026amp; Kinetic Studies\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-CBMZdwu0noRDNpx9HmjcMfyEnld\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-PDC2dEWojopaS7xith5cvQsFn6d\"\u003e\u003cstrong\u003eStandard Package Contents\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-FEvhdopCworRJVxcsjPcYt2bnSe\"\u003e•H-type quartz glass cell body (left + right chambers)\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-BeBydIKzto8yuhx2xxjcNAKnnSd\"\u003e•PTFE sealing caps\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Tvmjdfvz9oeMZ8xYA9KcPVH0nte\"\u003e•Electrode port screws (for electrode \u0026amp; gas use)\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-NssldOPjooJca4xXJCec7eitn7c\"\u003e•Chemical-resistant O-rings\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-GH7SdUvZHo1t2Nxyz8xcddu8nNN\"\u003e•Gas tubing connectors\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-B1hodrYpLoUjHFxWfQLcxvb0nOd\"\u003e•Membrane clamping interface\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-OC0md7G6toSILpxVxg4c7WVen3g\"\u003e\n\u003cstrong\u003eNote\u003c\/strong\u003e: Electrodes and membranes are \u003cstrong\u003enot included\u003c\/strong\u003e and must be configured separately.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-EaYcdbyEhomX3ox75tWcOZzMnQ6\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-K7CMdy4AioM2Lsxj4EicsEXZnJd\"\u003e\u003cstrong\u003eOptional Customization\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-NaxCdxzn6obhblxj2Nxca9ZHnIb\"\u003eAvailable upon request:\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-XLk5dHR61oZLy8xaFOmcmIONnQf\"\u003e•\u003cstrong\u003eQuartz\u003c\/strong\u003e\u003cstrong\u003e optical windows\u003c\/strong\u003e (UV \/ deep-UV compatible)\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-B8rKd75x6oRLwKxGEjOcKksZn1g\"\u003e•\u003cstrong\u003eCustom chamber volume ratios\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-KLmHdMcpeoCZShxIVODcivWpnMe\"\u003e•\u003cstrong\u003eAngled optical ports\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-O600dOhI6o4GYtxXGUNcNNG1nvb\"\u003e•\u003cstrong\u003eHigh-temperature glass\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-D9J5d15TsoW3puxsuukclb6ZnTc\"\u003e•\u003cstrong\u003ePressure-reinforced sealing\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-SfuqdGD1foiidzxIAYScehfqnSg\"\u003e•\u003cstrong\u003eIntegrated electrode holders\u003c\/strong\u003e (PEEK \/ PTFE)\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-I2eIdw1z3o0DDAx2ZpvcZ59bnzh\"\u003e•\u003cstrong\u003ePre-assembled \u003c\/strong\u003e\u003cstrong\u003emembrane\u003c\/strong\u003e\u003cstrong\u003e module\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-DWHbdb6mEo8lfPxNm71c1B5onNh\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-WWU9dcLUNouN9oxHsyZcZltbnWC\"\u003e\u003cstrong\u003eFor Custom Orders or Inquiries\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-VP7ldGZNLoawiDxGksdcMclgn8b\"\u003eIf you have custom requirements or any additional questions, feel free to contact us:\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Pkr5devg6oTudMxFB72c4GTonie\"\u003e\n\u003cstrong\u003eEmail\u003c\/strong\u003e: \u003cu\u003e\u003ca data-lark-is-custom=\"true\" href=\"mailto:support@franklab.shop\"\u003esupport@franklab.shop\u003c\/a\u003e\u003c\/u\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-VJSGdyzSyoNUT6xWIEOclNxFnUd\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-F9r1ddkIYo7dBuxw2UccQTAAnjf\"\u003e\u003cstrong\u003eWhy Choose FrankLab?\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-DlEid1z5HooepvxFgu4c5Jm9nsm\"\u003eFrankLab electrochemical cells are designed by electrochemists, for electrochemists. We emphasize:\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-OUBedKFyOoH5SBxeuzocnywgnmB\"\u003e•\u003cstrong\u003eClean Geometry\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-BJUHd4z36oxyNixXoWacvyKvnyg\"\u003e•\u003cstrong\u003eChemical Reliability\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Qy7Jdwe9MoYYmZxnKDQcK4tKnDg\"\u003e•\u003cstrong\u003eExperimental Reproducibility\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-XkQcdsuqzowAZXxuB2YczBdsnog\"\u003e•\u003cstrong\u003eCompatibility with Real Research Workflows\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-EZ6adG4ZIovHKNxLSmJc1g3fnid\"\u003eUsed by universities, national labs, and industrial R\u0026amp;D teams worldwide.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Franklab","offers":[{"title":"5*5*5cm","offer_id":44667629535266,"sku":null,"price":385.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/7008\/4386\/files\/image_20251223231109_a21874150613f9bb4769a1aa012c29d7.jpg?v=1766502711","url":"https:\/\/franklab.shop\/products\/h-type-sealed-quartz-optical-electrochemical-cell","provider":"Franklab","version":"1.0","type":"link"}