{"product_id":"handheld-potentiostat-mini-portable-electrochemical-workstation-electrochemical-analyzer","title":"Handheld Potentiostat – Mini Portable Electrochemical Workstation，Electrochemical Analyzer","description":"\u003cp class=\"p1\"\u003e\u003cb\u003eProduct Overview\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eThe Mini Portable Electrochemical Workstation is a compact, high-precision electrochemical analyzer designed for \u003cb\u003elaboratory research, biosensing, and field electrochemical detection\u003c\/b\u003e. With an ultra-small form factor and wireless Bluetooth communication, the device enables researchers to perform electrochemical measurements conveniently in both laboratory and portable environments.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eDespite its compact size, the system supports \u003cb\u003emultiple electrochemical testing methods\u003c\/b\u003e commonly used in electrochemical analysis and sensor development. The workstation provides \u003cb\u003epA-level current measurement sensitivity\u003c\/b\u003e, making it suitable for high-sensitivity electrochemical sensing applications.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eThe device is particularly suitable for \u003cb\u003ewearable electrochemical sensors, biosensor development, educational experiments, and portable electrochemical testing\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp class=\"p3\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eKey Features\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eUltra-Compact Design\u003c\/b\u003e\u003cbr\u003eSmall form factor measuring only \u003cb\u003e3.7 × 3.7 × 1.5 cm\u003c\/b\u003e, making it easy to carry and integrate into portable sensing systems.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eHigh Sensitivity Measurement\u003c\/b\u003e\u003cbr\u003eSupports \u003cb\u003epA-level current detection\u003c\/b\u003e, enabling precise electrochemical signal measurement.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eMultiple Electrochemical Methods\u003c\/b\u003e\u003cbr\u003eSupports \u003cb\u003e7 commonly used electrochemical techniques\u003c\/b\u003e for versatile research applications.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eWireless Data Communication\u003c\/b\u003e\u003cbr\u003eBuilt-in \u003cb\u003eBluetooth connectivity\u003c\/b\u003e enables wireless data transmission and convenient device operation.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eFlexible Electrode Compatibility\u003c\/b\u003e\u003cbr\u003eCompatible with common electrochemical electrode interfaces and supports dual working electrode configurations.\u003c\/p\u003e\n\u003cp class=\"p3\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eSupported Electrochemical Methods\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" class=\"t1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" class=\"td1\"\u003e\n\u003cp class=\"p4\"\u003e\u003cb\u003eMethod\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"td1\"\u003e\n\u003cp class=\"p4\"\u003e\u003cb\u003eFull Name\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" class=\"td1\"\u003e\n\u003cp class=\"p2\"\u003eCV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"td1\"\u003e\n\u003cp class=\"p2\"\u003eCyclic Voltammetry\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" class=\"td1\"\u003e\n\u003cp class=\"p2\"\u003eDPV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"td1\"\u003e\n\u003cp class=\"p2\"\u003eDifferential Pulse Voltammetry\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" class=\"td1\"\u003e\n\u003cp class=\"p2\"\u003eSWV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"td1\"\u003e\n\u003cp class=\"p2\"\u003eSquare Wave Voltammetry\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" class=\"td1\"\u003e\n\u003cp class=\"p2\"\u003eLSV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"td1\"\u003e\n\u003cp class=\"p2\"\u003eLinear Sweep Voltammetry\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" class=\"td1\"\u003e\n\u003cp class=\"p2\"\u003eEIS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"td1\"\u003e\n\u003cp class=\"p2\"\u003eElectrochemical Impedance Spectroscopy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" class=\"td1\"\u003e\n\u003cp class=\"p2\"\u003eOCP\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"td1\"\u003e\n\u003cp class=\"p2\"\u003eOpen Circuit Potential\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" class=\"td1\"\u003e\n\u003cp class=\"p2\"\u003ei–t\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"td1\"\u003e\n\u003cp class=\"p2\"\u003eChronoamperometry\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eVoltage Range\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e± \u003cb\u003e1.2 V\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003ePotentiostatic Control Range\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003e−1.7 V to +2.0 V\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eCurrent Measurement Range\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e± \u003cb\u003e3 mA\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eCurrent Ranges\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e•3 mA\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e•600 µA\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e•300 µA\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e•100 µA\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e•60 µA\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e•30 µA\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e•6 µA\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eData Communication\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eBluetooth wireless transmission\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eDevice Dimensions\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003e3.7 × 3.7 × 1.5 cm\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p3\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eElectrode Configuration\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eThe device supports a \u003cb\u003efour-electrode interface\u003c\/b\u003e including dual working electrodes.\u003c\/p\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" class=\"t1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" class=\"td1\"\u003e\n\u003cp class=\"p4\"\u003e\u003cb\u003eElectrode\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"td1\"\u003e\n\u003cp class=\"p4\"\u003e\u003cb\u003eDescription\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" class=\"td1\"\u003e\n\u003cp class=\"p2\"\u003eWE0\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"td1\"\u003e\n\u003cp class=\"p2\"\u003eWorking Electrode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" class=\"td1\"\u003e\n\u003cp class=\"p2\"\u003eWE1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"td1\"\u003e\n\u003cp class=\"p2\"\u003eWorking Electrode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" class=\"td1\"\u003e\n\u003cp class=\"p2\"\u003eCE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"td1\"\u003e\n\u003cp class=\"p2\"\u003eCounter Electrode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" class=\"td1\"\u003e\n\u003cp class=\"p2\"\u003eRE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" class=\"td1\"\u003e\n\u003cp class=\"p2\"\u003eReference Electrode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eTypical Applications\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eThe portable electrochemical workstation is suitable for:\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e•Electrochemical sensing\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e•Biosensor development\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e•Wearable electrochemical sensors\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e•Environmental monitoring\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e•Educational laboratory experiments\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e•Portable field electrochemical analysis\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e•Electrochemical research\u003c\/p\u003e\n\u003cp class=\"p3\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eStandard Package Includes\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e•Portable Electrochemical Workstation (Main Unit)\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e•Screen-Printed Electrode Adapter (3-electrode)\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e•Screen-Printed Electrode Adapter (4-electrode)\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e•Electrode Alligator Clip Cable\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e•USB Charging Cable\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e•Software Installation USB Drive\u003c\/p\u003e\n\u003cp class=\"p3\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eCore Advantages\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003ePortable Design\u003c\/b\u003e\u003cbr\u003eUltra-compact size suitable for laboratory and field applications.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eHigh Sensitivity Detection\u003c\/b\u003e\u003cbr\u003eSupports pA-level current measurement for advanced electrochemical sensing.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eMultiple Testing Modes\u003c\/b\u003e\u003cbr\u003eIntegrated electrochemical methods for diverse analytical needs.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eWireless Connectivity\u003c\/b\u003e\u003cbr\u003eBluetooth communication enables convenient real-time data transmission.\u003c\/p\u003e\n\u003cp class=\"p3\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eFor Custom Orders or Inquiries\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eIf you have custom requirements or any additional questions, feel free to contact us:\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eEmail\u003c\/b\u003e: support@franklab.shop\u003c\/p\u003e\n\u003cp class=\"p3\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eWhy Choose FrankLab?\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eFrankLab Focused on \u003cb\u003eelectrochemical \u0026amp; research materials\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e•Stable quality for repeatable experiments\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e•Flexible customization capability\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e•Trusted by universities, institutes, and industrial R\u0026amp;D labs\u003c\/p\u003e","brand":"Franklab","offers":[{"title":"Standard Kit","offer_id":44953140068386,"sku":null,"price":2800.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/7008\/4386\/files\/2_584f241a-1b06-4613-9b6f-aaaa30328f3b.png?v=1772699828","url":"https:\/\/franklab.shop\/products\/handheld-potentiostat-mini-portable-electrochemical-workstation-electrochemical-analyzer","provider":"Franklab","version":"1.0","type":"link"}