{"product_id":"in-situ-raman-spectroelectrochemical-cell-h-type-gas-diffusion-cell-serpentine-flow-field","title":"In-situ Raman Spectroelectrochemical Cell [H-Type Gas Diffusion Cell – Serpentine Flow Field]","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"collapsible-content collapsible-content--all is-open\" id=\"Product-description-15097760120992-15097760120992\"\u003e\n\u003cdiv class=\"collapsible-content__inner rte\"\u003e\n\u003cp data-end=\"610\" data-start=\"341\"\u003eThis in-situ electrochemical cell features a serpentine gas flow channel in the cathode chamber. The design extends the contact time between gas and catalyst, significantly improving gas participation in electrochemical reactions.\u003c\/p\u003e\n\u003cp data-end=\"912\" data-start=\"612\"\u003eBuilt with a durable PEEK body and a sapphire optical window directly above the working electrode, the cell supports real-time spectroscopic analysis. The dual-chamber structure with user-supplied membrane separates cathode and anode chambers, and the built-in reference electrode minimizes R_drop.\u003c\/p\u003e\n\u003cp data-end=\"1044\" data-start=\"914\"\u003eCompatible with gas-diffusion and planar electrodes, it is suitable for both flow systems and injection-based electrolyte filling.\u003c\/p\u003e\n\u003cp data-end=\"1064\" data-start=\"1046\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"1064\" data-start=\"1046\"\u003e\u003cmeta charset=\"utf-8\"\u003e•PEEK body with fast assembly and easy cleaning\u003c\/p\u003e\n\u003cp data-end=\"1173\" data-start=\"1118\"\u003e\u003cmeta charset=\"utf-8\"\u003e•Sapphire window (37 mm), \u0026lt;6 mm from working electrode\u003c\/p\u003e\n\u003cp data-end=\"1247\" data-start=\"1176\"\u003e\u003cmeta charset=\"utf-8\"\u003e•Serpentine gas flow channel in cathode chamber for improved diffusion\u003c\/p\u003e\n\u003cp data-end=\"1306\" data-start=\"1250\"\u003e\u003cmeta charset=\"utf-8\"\u003e•Dual-chamber design with user-replaceable ion membrane\u003c\/p\u003e\n\u003cp data-end=\"1355\" data-start=\"1309\"\u003e\u003cmeta charset=\"utf-8\"\u003e•Supports gas-diffusion and planar electrodes\u003c\/p\u003e\n\u003cp data-end=\"1422\" data-start=\"1358\"\u003e\u003cmeta charset=\"utf-8\"\u003e•Standard Ag\/AgCl RE and graphite CE (Ag⁺\/Pt options available)\u003c\/p\u003e\n\u003cp data-end=\"1422\" data-start=\"1358\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003eInjection and flow system compatible\u003c\/p\u003e\n\u003cp data-end=\"1498\" data-start=\"1470\"\u003e\u003cstrong\u003eProduct Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"_tableContainer_16hzy_1\"\u003e\n\u003cdiv class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"3312\" data-start=\"1500\" height=\"500\"\u003e\n\u003cthead data-end=\"1612\" data-start=\"1500\"\u003e\n\u003ctr data-end=\"1612\" data-start=\"1500\"\u003e\n\u003cth data-col-size=\"sm\" data-end=\"1531\" data-start=\"1500\"\u003eItem\u003c\/th\u003e\n\u003cth data-col-size=\"md\" data-end=\"1612\" data-start=\"1531\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"3312\" data-start=\"1726\"\u003e\n\u003ctr data-end=\"1839\" data-start=\"1726\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1757\" data-start=\"1726\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"1839\" data-start=\"1757\"\u003eC031-3S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"1952\" data-start=\"1840\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1871\" data-start=\"1840\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"1952\" data-start=\"1871\"\u003eIn-situ Raman\/optical electrochemical studies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2066\" data-start=\"1953\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"1984\" data-start=\"1953\"\u003eCell Body Material\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2066\" data-start=\"1984\"\u003ePEEK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2179\" data-start=\"2067\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2098\" data-start=\"2067\"\u003eOptical Window Material\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2179\" data-start=\"2098\"\u003eSapphire (1 mm thickness)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2293\" data-start=\"2180\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2211\" data-start=\"2180\"\u003eOptical Window Diameter\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2293\" data-start=\"2211\"\u003e37 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2407\" data-start=\"2294\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2325\" data-start=\"2294\"\u003eDistance (WE to Window)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2407\" data-start=\"2325\"\u003e\u0026lt; 6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2520\" data-start=\"2408\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2439\" data-start=\"2408\"\u003eWorking Electrode Area\u003c\/td\u003e\n\u003ctd data-end=\"2520\" data-start=\"2439\" data-col-size=\"md\"\u003e1 cm² (customizable upon request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2633\" data-start=\"2521\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2552\" data-start=\"2521\"\u003eSupported Electrode Types\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2633\" data-start=\"2552\"\u003eGas-diffusion \u0026amp; planar electrodes (Au, Pt, GC, ITO, FTO, etc.; not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2746\" data-start=\"2634\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2665\" data-start=\"2634\"\u003eReference Electrode\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2746\" data-start=\"2665\"\u003eAg\/AgCl (standard); optional Ag⁺\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2859\" data-start=\"2747\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2778\" data-start=\"2747\"\u003eCounter Electrode\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2859\" data-start=\"2778\"\u003eGraphite rod (standard); optional Pt wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2972\" data-start=\"2860\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2891\" data-start=\"2860\"\u003eGas Flow Channel\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2972\" data-start=\"2891\"\u003eSerpentine flow design in cathode chamber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3085\" data-start=\"2973\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3004\" data-start=\"2973\"\u003eElectrolyte Filling\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"3085\" data-start=\"3004\"\u003eInjection method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3199\" data-start=\"3086\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3117\" data-start=\"3086\"\u003eFlow System Compatible\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"3199\" data-start=\"3117\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3312\" data-start=\"3200\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3231\" data-start=\"3200\"\u003eChamber Separation\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"3312\" data-start=\"3231\"\u003eIon-exchange membrane (user-supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp data-end=\"3341\" data-start=\"3319\"\u003e\u003cstrong\u003ePackage Includes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e•Electrochemical Cell (C031-3S)\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e•Sapphire Optical Window\u003c\/p\u003e\n\u003cp data-end=\"3436\" data-start=\"3407\"\u003e\u003cmeta charset=\"utf-8\"\u003e•Ag\/AgCl Reference Electrode\u003c\/p\u003e\n\u003cp data-end=\"3471\" data-start=\"3439\"\u003e\u003cmeta charset=\"utf-8\"\u003e•Graphite Rod Counter Electrode\u003c\/p\u003e\n\u003cp data-end=\"3501\" data-start=\"3474\"\u003e\u003cmeta charset=\"utf-8\"\u003e•Standard Fittings \u0026amp; Seals\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eFor Custom Orders or Inquiries\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eIf you have custom requirements or any additional questions, feel free to contact us:\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eEmail\u003c\/b\u003e: support@franklab.shop\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Franklab","offers":[{"title":"H-Type Gas Diffusion Cell – Serpentine Flow Field","offer_id":44634159579170,"sku":null,"price":2580.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/7008\/4386\/files\/ScreenShot_2025-12-11_155153_363.png?v=1766479530","url":"https:\/\/franklab.shop\/products\/in-situ-raman-spectroelectrochemical-cell-h-type-gas-diffusion-cell-serpentine-flow-field","provider":"Franklab","version":"1.0","type":"link"}