{"product_id":"multifunctional-in-situ-electrochemical-cell","title":"Multifunctional In-Situ Electrochemical Cell","description":"\u003cdiv data-docx-has-block-data=\"true\" data-lark-html-role=\"root\" data-page-id=\"DMgyd3dtNonZL1xxabRcLu9Fn5d\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-HDuVddCKNoHhdixLjzjcJJaJnjf\"\u003e\u003cstrong style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 0.875rem;\"\u003eProduct Overview\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-V833d7UYdoS2zExr3NrczD7Ankd\"\u003eThe \u003cstrong\u003eMultifunctional In-Situ Electrochemical Flow Cell\u003c\/strong\u003e is a \u003cstrong\u003eresearch-grade, modular electrochemical platform\u003c\/strong\u003e engineered for \u003cstrong\u003ereal-time\u003c\/strong\u003e\u003cstrong\u003e electrochemical, spectroscopic, and structural characterization\u003c\/strong\u003e under controlled flow conditions.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-MWg0diOWJoz40SxrGYvcJbBknwp\"\u003eDesigned around a \u003cstrong\u003ereplaceable front-window architecture\u003c\/strong\u003e and a \u003cstrong\u003eserpentine flow channel\u003c\/strong\u003e, this cell allows researchers to seamlessly switch between \u003cstrong\u003eRaman, \u003c\/strong\u003e\u003cstrong\u003eUV\u003c\/strong\u003e\u003cstrong\u003e–Vis, \u003c\/strong\u003e\u003cstrong\u003eXRD\u003c\/strong\u003e\u003cstrong\u003e, XAFS, and optical microscopy\u003c\/strong\u003e without redesigning the electrochemical core.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-DX4kdVciioaewmx7T7accdkXn6f\"\u003eUnlike conventional fixed-window cells, this platform decouples \u003cstrong\u003eelectrochemical functionality\u003c\/strong\u003e from \u003cstrong\u003eoptical interface selection\u003c\/strong\u003e, enabling one base cell to support \u003cstrong\u003emultiple in-situ techniques\u003c\/strong\u003e with high reproducibility.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-RLWfdscMaoMZmKxWtyHcOzO1ndl\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-LMmNdpY66o2e2LxQH8ScXtIin3b\"\u003e\u003cstrong\u003e Core Architecture\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-ONoOdwptfo7PAHxAtbZcW0yfnTb\"\u003e\u003cstrong\u003eModular Flow-Cell Design\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-XKX5dS333ooO5Gxe28McmRLRnEg\"\u003e•Electrolyte enters the chamber via the \u003cstrong\u003ereference electrode inlet\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-UoHQdq4l8oNkMaxzzJwc1ge1n6e\"\u003e•Flows across the \u003cstrong\u003eworking electrode surface\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-QwIddlBvbopI8KxJBiWcEFFinnd\"\u003e•Exits through the \u003cstrong\u003ecounter electrode outlet\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-KU3jd5yp3ofkCExI4REcDhcnnef\"\u003e•Forms a \u003cstrong\u003eclosed, well-defined flow loop\u003c\/strong\u003e with minimal dead volume\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-B8tAdVcHJoP8RIxogFZcDJQVnOd\"\u003e\u003cstrong\u003eSerpentine Flow Field\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-AhlhdmiWCo5JzBxmyeqcVS9ynQe\"\u003e•Channel size: \u003cstrong\u003e15 × 15 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-EN88dqyZ2oaLarxtYOZcl564nqb\"\u003e•Channel depth: \u003cstrong\u003e1.2 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-MAsqdh7Nnox4tcxRFtmcyfZtnKb\"\u003e•Enhances mass transport and residence time\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-D3bBdnUcpo1wouxfv1Mc2Okjnmg\"\u003e•Ideal for kinetics-sensitive reactions and durability tests\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-TXizdeLvioezVdxoCwXcOY3inNh\"\u003e\u003cstrong\u003eDual Working-Electrode Modes\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-DvCQdGufnoAkVkxiCixc2l3RnIg\"\u003e•\u003cstrong\u003eStandard planar contact mode\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-ZpxKdSmRPoHSZmx9ofachGunnMb\"\u003e•\u003cstrong\u003eGas diffusion electrode (GDE) mode\u003c\/strong\u003e for gas-involved reactions\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-MFjbdUUxao4Ctgx551ackrtznJf\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-W511dm0HJoeGtUxDd6UcmLpZnDe\"\u003e\u003cstrong\u003e Window-Exchange System (Key Differentiator)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-OSk6dhdQZoWh5pxlW3FchRClnpd\"\u003eThe front observation window is \u003cstrong\u003efully replaceable\u003c\/strong\u003e, allowing rapid adaptation to different characterization techniques:\u003c\/div\u003e\n\u003cdiv class=\"old-record-id-JQqLdiVmDoDginx9YUccETQtnfU\" data-type=\"sheet\"\u003e\n\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"105\"\u003e \u003ccol width=\"105\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"46\"\u003e\n\u003ctd\u003eWindow Material\u003c\/td\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"65\"\u003e\n\u003ctd\u003eQuartz\u003c\/td\u003e\n\u003ctd\u003eOptical imaging, UV–Vis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"46\"\u003e\n\u003ctd\u003eSapphire\u003c\/td\u003e\n\u003ctd\u003eIn-situ Raman, UV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eKapton (PI)\u003c\/td\u003e\n\u003ctd\u003eXAFS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eBeryllium (Be)\u003c\/td\u003e\n\u003ctd\u003eIn-situ XRD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-T4XIdMMZvoI3zdxQFFccw74knuf\"\u003e✔ No redesign of the electrochemical body required\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-EmDwd4tLwosq9UxrC82chCfAnec\"\u003e✔ Maintains identical electrochemical geometry across techniques\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-HRu7dzEXHor8GpxQJ8ucYDqnnZg\"\u003e✔ Ideal for cross-technique data correlation\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-TebAdHANGoOiZnxEIO6cXbQun4f\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-CaEQdSfAVoRyTuxlLLncedYnnvc\"\u003e\u003cstrong\u003e Materials \u0026amp; Construction\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"old-record-id-V4WOdzfonoNXe6xXFgBc1ZMSnQh\" data-type=\"sheet\"\u003e\n\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"164\"\u003e \u003ccol width=\"272\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eComponent\u003c\/td\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eCell body\u003c\/td\u003e\n\u003ctd\u003ePEEK (chemically resistant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eStructural reinforcement\u003c\/td\u003e\n\u003ctd\u003eHigh-purity titanium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eFlow plates\u003c\/td\u003e\n\u003ctd\u003ePrecision-machined metal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eSealing\u003c\/td\u003e\n\u003ctd\u003eChemical-resistant gaskets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eFasteners\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-GJ65dmC1So9Q7zxA5X7cWpnynyb\"\u003eDesigned for \u003cstrong\u003erapid assembly \/ \u003c\/strong\u003e\u003cstrong\u003edisassembly\u003c\/strong\u003e and \u003cstrong\u003eeasy cleaning\u003c\/strong\u003e, even during frequent window changes.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-QE3IdCgeXoysZIxDnjRcFMPdnWe\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Mvd4djCBjoo9pixyKiRc8ugSnYe\"\u003e\n\u003cstrong\u003e \u003c\/strong\u003e\u003cstrong\u003eElectrode\u003c\/strong\u003e\u003cstrong\u003e Configuration\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-WXOxdsB87o7EslxalWqcFZVJnOB\"\u003e\n\u003cstrong\u003eWorking \u003c\/strong\u003e\u003cstrong\u003eElectrode\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Gknyd9A68oXcApxV5IgcHfjfnVg\"\u003e•Planar electrodes or gas diffusion electrodes\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Qa94d31eioe9pwxLbD9ctUhQnBd\"\u003e•Compatible materials: Au, Pt, Ag, GC, graphite, carbon paper, custom substrates\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-DMp5dQnnGobiFtxRsiDcxguLnEg\"\u003e\n\u003cstrong\u003eReference \u003c\/strong\u003e\u003cstrong\u003eElectrode\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-FCcKdSd6soLhH3xjB2Mc9HhXnUd\"\u003e•Ag\/AgCl or Ag⁺\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-XbztdGFPioYaDBxJFiNckCmtnqh\"\u003e\n\u003cstrong\u003eCounter \u003c\/strong\u003e\u003cstrong\u003eElectrode\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-N9Q1dmI3Yoissmxy0PrckRbwnkf\"\u003e•Platinum wire or graphite rod\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-P5SQdkQ0hoO1d5x6a9XcMKdRn8g\"\u003eAll electrodes are positioned to \u003cstrong\u003eminimize solution resistance (Rₛ)\u003c\/strong\u003e and ensure stable potential control.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-CzT0dPlZ2oGhfxxA6PJc0r51nOc\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-WUeQdW7GnoQf6kxHnsTcvlDvnab\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"old-record-id-VUQYdEeWVoP4Ogxdo7ocJYL2nkf\" data-type=\"sheet\"\u003e\n\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"193\"\u003e \u003ccol width=\"230\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eParameter\u003c\/td\u003e\n\u003ctd\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"46\"\u003e\n\u003ctd\u003eCell type\u003c\/td\u003e\n\u003ctd\u003eMultifunctional in-situ flow electrochemical cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eFlow channel depth\u003c\/td\u003e\n\u003ctd\u003e1.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eFlow field\u003c\/td\u003e\n\u003ctd\u003eSerpentine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eActive area\u003c\/td\u003e\n\u003ctd\u003e15 × 15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eWindow format\u003c\/td\u003e\n\u003ctd\u003eModular, replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eElectrolyte mode\u003c\/td\u003e\n\u003ctd\u003eContinuous flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eGas compatibility\u003c\/td\u003e\n\u003ctd\u003eYes (GDE mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eAssembly\u003c\/td\u003e\n\u003ctd\u003eTool-assisted, modular\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eCleaning\u003c\/td\u003e\n\u003ctd\u003eFully disassemblable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-XfVvdahjRoR23Xx4OLTcKIfinOh\"\u003e\u003cstrong\u003e Typical Applications\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-WpZ8d0FMqoPrmgxon0ccEOA3n8b\"\u003e•In-situ Raman spectroscopy under flow\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-QIvMdU2I9ohV36xPTrRcwLG4nVb\"\u003e•In-situ XRD during electrochemical phase transitions\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Z9CfdKw4CoBhhixTT2scU7xln7e\"\u003e•XAFS studies with Kapton window\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-V0dndLEcDoedrpxbZ0tck7xfnLf\"\u003e•Gas-involved electrochemistry (CO₂RR, ORR, HER)\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-F43DdIgsfoTDzExlks8c1zVunpb\"\u003e•Catalyst stability and degradation studies\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-UFSidAhB7odfoGxaQ13cyAcInye\"\u003e•Correlative electrochemistry–spectroscopy workflows\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-KaXndzw2EoWzyyxbBy5cN97GnMf\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Fe83d9BLqoDXWjxAIUZcu48innc\"\u003e\u003cstrong\u003e Standard Package Contents\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-VfoSdkjHMotNYHxMyb8ckdKqnNc\"\u003e•Electrochemical flow cell body\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Czz5d5TMTovqOuxPjnYcGmPnnod\"\u003e•Serpentine flow plate\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-G0RidhgyroMO51xHv3icCedfnRc\"\u003e•Modular window frame\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Z37ldA3NNol9Jnx9t4Actkt8ntm\"\u003e•Sealing gaskets\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-V48NdzBoGoCRLaxtyawc2a5jntf\"\u003e•Electrode ports and fittings\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-NnkodEFDBofbz8xPSoCcYlWfnof\"\u003e\n\u003cem\u003e(Windows, electrodes, \u003c\/em\u003e\u003cem\u003emembranes\u003c\/em\u003e\u003cem\u003e selected according to experiment and supplied separately or as configured kits)\u003c\/em\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-NnkodEFDBofbz8xPSoCcYlWfnof\"\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eFor Custom Orders or Inquiries\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eIf you have custom requirements or any additional questions, feel free to contact us:\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eEmail\u003c\/b\u003e: support@franklab.shop\u003c\/p\u003e","brand":"Franklab","offers":[{"title":"Multifunctional","offer_id":44634428375074,"sku":null,"price":2590.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/7008\/4386\/files\/Multifunctional-In-Situ-Electrochemical-Cell-1.jpg?v=1773977348","url":"https:\/\/franklab.shop\/products\/multifunctional-in-situ-electrochemical-cell","provider":"Franklab","version":"1.0","type":"link"}