{"product_id":"sealed-electrolytic-cell-30ml-1000ml","title":"Sealed Electrochemical Cell [30ml-1000ml]","description":"\u003cdiv data-docx-has-block-data=\"true\" data-lark-html-role=\"root\" data-page-id=\"UJVvdWU41o3Hvox4MC4cAs0Rncb\"\u003e\n\u003ch4 class=\"heading-2 ace-line old-record-id-Xre6d80hQo1EBUxiY9ucygElnhe\"\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-VpJqdjGs8oOHRWxyCzsc0m7cnld\"\u003eThe \u003cstrong\u003eFrankLab Sealed Electrochemical Cell\u003c\/strong\u003e is a fully enclosed electrochemical reactor engineered for \u003cstrong\u003econtrolled-environment electrochemical experiments\u003c\/strong\u003e, where gas isolation, electrolyte stability, and experimental reproducibility are critical.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-GR8XdEXCOoOtWUxSwc8cqvbzndf\"\u003eWith a \u003cstrong\u003egas-tight sealing structure\u003c\/strong\u003e and modular electrode access, this cell is ideal for \u003cstrong\u003elong-term \u003c\/strong\u003e\u003cstrong\u003eelectrolysis\u003c\/strong\u003e, \u003cstrong\u003egas-involved reactions\u003c\/strong\u003e, and \u003cstrong\u003esensitive mechanistic studies\u003c\/strong\u003e. The wide capacity range from \u003cstrong\u003e30 mL to 1000 mL\u003c\/strong\u003e supports both small-scale screening and extended performance testing.\u003c\/div\u003e\n\u003ch4 class=\"heading-2 ace-line old-record-id-OPIPdl5fcojpe2xrLKscVMIknRc\"\u003e\u003cstrong\u003eCell Design \u0026amp; Structure\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-ZxpjdlZLyoNFeoxLvMmcq2ejnJf\"\u003e• Fully sealed electrochemical cell body\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-UN70d2nhzoPCd3xrSzhcSfyZnQg\"\u003e• Modular PTFE sealing system\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-SL8ddWnvgoPr6uxEEfJczyK9n5c\"\u003e• Independent electrode and gas ports\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-EGA0d4AQNot4guxqydZcBjHon4c\"\u003e• Stable geometry for reproducible measurements\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Wz0ld20w7oGFOVx0ASBc3GONnCd\"\u003e✔ Designed for clean, controlled electrochemical environments\u003c\/div\u003e\n\u003ch4 class=\"heading-2 ace-line old-record-id-UQv7dRjXIo3tG1xtu2Jcc7s3nPe\"\u003e\u003cstrong\u003eAvailable Capacities\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-XnJnd90xcoBnojx4xKUcr1pUn8H\"\u003e\u003cem\u003e(Single-cell volume options)\u003c\/em\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-OKubdclxeonYjFxOemYcXIZinWh\"\u003e• 30 mL\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-VGCJdlEO1oEWtPxQ4BfcjMtSnZe\"\u003e• 50 mL\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-VbfWdWQjpookXLxWlhGcmcWNnid\"\u003e• 100 mL\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-QZmodAxMMoQhQDxOhyPcwiqrnnd\"\u003e• 150 mL\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-SOmwdNtYGoTpDaxFGqwcY73rnmg\"\u003e• 200 mL\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-SGqRdYhzqo8G3Kx0S4GcdKVZnec\"\u003e• 250 mL\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-WQZSdifj5ohvFmxrOJxc22wDnyb\"\u003e• 300 mL\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-HpmLdWECwoZehBxetKBcjXdBnsd\"\u003e• 500 mL\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-UlfgdZSHcodE98xQ3w7cEf2xnPh\"\u003e• 1000 mL\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-YQyAdcXpToKfutxCMFHcJIaanWh\"\u003eCustom capacities and configurations are available upon request.\u003c\/div\u003e\n\u003ch4 class=\"heading-2 ace-line old-record-id-UHMkd2uEnogbVKxG9abcPxMine8\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv class=\"old-record-id-FMyVdRavVoNMw3xFwEQcOX5Nngc\" data-type=\"sheet\"\u003e\n\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"178\"\u003e \u003ccol width=\"413\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eParameter\u003c\/td\u003e\n\u003ctd\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eCell type\u003c\/td\u003e\n\u003ctd\u003eSealed electrochemical cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eBody material\u003c\/td\u003e\n\u003ctd\u003eHigh-purity borosilicate glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eSealing method\u003c\/td\u003e\n\u003ctd\u003ePTFE caps with chemical-resistant O-rings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eElectrode ports\u003c\/td\u003e\n\u003ctd\u003eWorking \/ Counter \/ Reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eGas ports\u003c\/td\u003e\n\u003ctd\u003eGas inlet \u0026amp; outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eOperating pressure\u003c\/td\u003e\n\u003ctd\u003eAtmospheric to low-pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eTemperature compatibility\u003c\/td\u003e\n\u003ctd\u003eRoom temperature to moderate heating*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eChemical resistance\u003c\/td\u003e\n\u003ctd\u003eAcidic, alkaline, and common organic electrolytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"ace-line ace-line old-record-id-DzXhdyc2foo6pexaQZgcx4gpnWf\"\u003e*Temperature limits depend on electrolyte and sealing configuration.\u003c\/h4\u003e\n\u003ch4 class=\"heading-2 ace-line old-record-id-I26gdg2myoYW5xx2qfRczLSyn0f\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch5 class=\"heading-3 ace-line old-record-id-NqBUdPIz1o7TE5xautRcdHXgn9f\"\u003e\u003cstrong\u003eGas-Tight Sealed Design\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-WZZPdQ3xboC1NGxLTMycpBf6nbe\"\u003ePrevents air ingress and electrolyte evaporation, ensuring stable electrochemical conditions during long-term experiments.\u003c\/div\u003e\n\u003ch5 class=\"heading-3 ace-line old-record-id-Sr79dx456oMJkWx6n1pcbQGDnzc\"\u003e\u003cstrong\u003eIndependent Atmosphere Control\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-WPXudsafWoIvaqxiSunccnBAnsc\"\u003eDedicated gas inlet and outlet ports allow controlled purging with \u003cstrong\u003eCO\u003c\/strong\u003e\u003cstrong\u003e₂, \u003c\/strong\u003e\u003cstrong\u003eAr\u003c\/strong\u003e\u003cstrong\u003e, N₂, O₂\u003c\/strong\u003e, or other reaction gases.\u003c\/div\u003e\n\u003ch5 class=\"heading-3 ace-line old-record-id-OPmydSrd1o003mxHuS3cj8mSnHg\"\u003e\n\u003cstrong\u003eBroad \u003c\/strong\u003e\u003cstrong\u003eElectrode\u003c\/strong\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-SZahdfvmOoXklmxT0dicOSNjnXb\"\u003eSupports common laboratory electrodes including:\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-IEaZd5XFUo779NxWuYhcLnjcnhe\"\u003e• Platinum, gold, and other metal electrodes\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-XqPBdq8bXobsPkxZcDEcnmAfnZg\"\u003e• Glassy carbon rods or plates\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-CGwQdB50eoPsIfxC5u2cz5SInGx\"\u003e• Ag\/AgCl, Hg\/HgO, SCE reference electrodes\u003c\/div\u003e\n\u003ch5 class=\"heading-3 ace-line old-record-id-B7wodd4xYoh11ixJU3Vc6FsFn4e\"\u003e\n\u003cstrong\u003eModular \u0026amp; Easy \u003c\/strong\u003e\u003cstrong\u003eMaintenance\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Q2XPdiv5roMyEUx95GXcKQBYnYc\"\u003eThe cell can be fully disassembled for cleaning, component replacement, and configuration changes.\u003c\/div\u003e\n\u003ch4 class=\"heading-2 ace-line old-record-id-BkWxdbpeSoc365xVSXScBb2dnhh\"\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Lys4dnvnDoGoaixrW14cVG6unRM\"\u003e• CO₂ reduction reaction (CO₂RR)\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-UGJfdQ3jJoSGMdxn8hdcmK5hnMd\"\u003e• Water electrolysis \u0026amp; hydrogen evolution\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-NsuCd3iL7o9qYpxSyrrcdouUnIh\"\u003e• Oxygen evolution reaction (OER) studies\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Sr7KdMeDJoL9BnxaaXKcFvMunio\"\u003e• Gas–liquid electrochemical interfaces\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-FftZd96oko79Gtx7a3ZcJKmLndd\"\u003e• Battery and redox chemistry research\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-FbvrdHaf2o7sVRxQp7Zcqrainje\"\u003e• Long-duration stability testing\u003c\/div\u003e\n\u003ch4 class=\"heading-2 ace-line old-record-id-YivJd2RUmouM1pxTH1KcUXrSnDb\"\u003e\u003cstrong\u003eStandard Package Contents\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-AJXQdtCP2oo47bxkBqyc3ThanJc\"\u003e• Sealed glass electrochemical cell body\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-KSIzdF4mGoEyrpxrI4FcaHg1nZf\"\u003e• PTFE sealing caps\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-SbTndnPRUoVAb8x57WRcdvFwnuc\"\u003e• Electrode port screws\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-HaFhdoYIfoXhbdx2lQGc62UpnFd\"\u003e• Gas inlet\/outlet fittings\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-PMyGdDv5CokhPDx7A88c80ornVd\"\u003e• Chemical-resistant O-rings\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-V6GidT41Jo1fVTxLXzYcVxDjn0f\"\u003eElectrodes are \u003cstrong\u003enot included\u003c\/strong\u003e by default.\u003c\/div\u003e\n\u003ch4 class=\"heading-2 ace-line old-record-id-YB2lddjBjobAuGxS9j1cQyCEndb\"\u003e\u003cstrong\u003eOptional Customization\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-UEdqdCghWoDkQOxpV7OcqpoDnnb\"\u003eAvailable upon request:\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-CxDHdvzhooJC1rx61k6cu2CYn7g\"\u003e• Custom cell volumes\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-JESrdW1s2ogFv9xFVMAccx1ynDe\"\u003e• Additional or modified electrode ports\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-DrDgde0V6ofMxXxoPXLckOucnwb\"\u003e• High-temperature sealing materials\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-G2JDdIurToyVW5xlkLhctGPInBd\"\u003e• Integrated electrode holders\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-KmtKd85ItoeZpTxNkzwcx9ZDnNf\"\u003e• Pre-configured gas fittings\u003c\/div\u003e\n\u003ch4 class=\"heading-2 ace-line old-record-id-LddldoQmtoyKsaxACetcY8HBn0b\"\u003e\u003cstrong\u003eFor Custom Orders or Technical Support\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-J5tSdjpMco3DWLxvbEOc9j5SnZf\"\u003eIf you have custom requirements or need assistance selecting the right configuration, please contact us:\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-CpfldG4LWoRxnQxwBKqcz1zLnre\"\u003e\u003cstrong\u003e\u003ca href=\"mailto:support@franklab.shop\" data-lark-is-custom=\"true\"\u003esupport@franklab.shop\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003ch2 class=\"heading-2 ace-line old-record-id-SyM0dD0W1o99JUxffTicdtA9nke\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch4 class=\"heading-2 ace-line old-record-id-SyM0dD0W1o99JUxffTicdtA9nke\"\u003e\u003cstrong\u003eWhy FrankLab\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-ZUJzdf3cmoWXqixxmwIcq1BTnTg\"\u003eFrankLab electrochemical cells are designed \u003cstrong\u003eby electrochemists, for electrochemists\u003c\/strong\u003e.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-P3Ord55UlovbCRxfYVGc0YBIn1F\"\u003eWe focus on:\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-O7oHdUBHWoRupvxRLC5cZgtbnJf\"\u003e• Clean geometry\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-UepZdLjsnoZozoxLEGNcw3nMnUd\"\u003e• Chemical reliability\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-VyVGd590VomokLx7PCdcolD6nne\"\u003e• Experimental reproducibility\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-RAhpd7JGookyVDx0ZphcDlR3nrd\"\u003e• Compatibility with real laboratory workflows\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-OmHudvwfBoq2iLxZv8uc6DDxnWc\"\u003eTrusted by universities, research institutes, and industrial R\u0026amp;D teams worldwide.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Franklab","offers":[{"title":"30 ml","offer_id":44553569599522,"sku":null,"price":69.9,"currency_code":"USD","in_stock":false},{"title":"50 ml","offer_id":44553569632290,"sku":null,"price":79.9,"currency_code":"USD","in_stock":false},{"title":"100 ml","offer_id":44553569665058,"sku":null,"price":89.9,"currency_code":"USD","in_stock":false},{"title":"150 ml","offer_id":44553569697826,"sku":null,"price":95.9,"currency_code":"USD","in_stock":false},{"title":"200 ml","offer_id":44553569730594,"sku":null,"price":99.9,"currency_code":"USD","in_stock":false},{"title":"250 ml","offer_id":44553569763362,"sku":null,"price":105.9,"currency_code":"USD","in_stock":false},{"title":"300 ml","offer_id":44553569796130,"sku":null,"price":109.9,"currency_code":"USD","in_stock":false},{"title":"500 ml","offer_id":44553569828898,"sku":null,"price":119.9,"currency_code":"USD","in_stock":false},{"title":"500 ml [ Extended Height ]","offer_id":44553569861666,"sku":null,"price":119.9,"currency_code":"USD","in_stock":false},{"title":"1000 ml","offer_id":44553569894434,"sku":null,"price":139.9,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/7008\/4386\/files\/Sealed-Electrochemical-Cell_30ml-1000ml_-1.jpg?v=1773910659","url":"https:\/\/franklab.shop\/products\/sealed-electrolytic-cell-30ml-1000ml","provider":"Franklab","version":"1.0","type":"link"}