{"product_id":"serpentine-chamber-flow-cell","title":"Serpentine-Chamber Flow Cell","description":"\u003cdiv data-page-id=\"YobidozjioLIrQxQOYCcYOnZngs\" data-lark-html-role=\"root\" data-docx-has-block-data=\"true\"\u003e\n\u003ch1 class=\"heading-1 ace-line old-record-id-S4mrdrxdToOK8zxzIamc7QX3nQf\"\u003e\u003cstrong\u003eSerpentine-Chamber Flow Cell\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-D9CrdZ4zvoXjM5xw4yTc4ICOnvf\"\u003e\u003cstrong\u003eAdvanced Gas Diffusion \u0026amp; Photoelectrochemical Flow Cell for High-Efficiency Electrocatalysis\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-V14Zd87uUoJV9Lx7nVlcDk9Fnzg\"\u003eThe \u003cstrong\u003eSerpentine-Chamber Flow Cell\u003c\/strong\u003e is a research-grade electrochemical reactor engineered for \u003cstrong\u003egas diffusion electrochemistry, photoelectrochemical studies, and membrane-assisted reactions\u003c\/strong\u003e where precise mass transport control is critical. By integrating a \u003cstrong\u003eserpentine flow-field architecture\u003c\/strong\u003e with a compact multi-electrode design, the cell significantly enhances reactant residence time, interfacial contact, and current density uniformity.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-VUhXdUrHLoHMEtxObV1c6RwGnYd\"\u003eDesigned for \u003cstrong\u003ePI-level research, doctoral studies, and engineering development\u003c\/strong\u003e, this cell supports rigorous electrochemical characterization while remaining modular, serviceable, and compatible with standard laboratory infrastructure.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-QUoBdqPJ1oWwWZxV3z4cJtvGnch\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-TdKudwipOopqVMxAj5QcBP9Sncf\"\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-OATfdNI7RoOz9bxXH2mcHWlxnUf\"\u003eThe cell adopts a \u003cstrong\u003elayered sandwich structure\u003c\/strong\u003e with a precision-machined \u003cstrong\u003eserpentine flow channel\u003c\/strong\u003e on the reaction side. This geometry forces the electrolyte or gas stream to follow a controlled, extended pathway, ensuring:\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-EujWdZNf7oUJt1xsC98cedbvnkb\"\u003e•Uniform reactant distribution across the electrode surface\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-PHdkdzFinoZqPAxBTWAcSwEenWd\"\u003e•Reduced concentration polarization\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Kx3gdu7igodyLFx5oh2cCSMMnDc\"\u003e•Improved catalyst utilization and reaction efficiency\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-BNHpdoToioImZrxmbDPcuYtXnKh\"\u003eThe reactor is compatible with \u003cstrong\u003egas diffusion electrodes (GDEs)\u003c\/strong\u003e, flat metal electrodes, and porous catalytic materials, making it suitable for \u003cstrong\u003eCO\u003c\/strong\u003e\u003cstrong\u003e₂ reduction, gas-phase electrocatalysis, and photo-assisted electrochemical reactions\u003c\/strong\u003e.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-ZsUBdTCkaottOqx02IkcLeqpnJb\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-FnVcdco9Go3Z5axQJMPc33BCngg\"\u003e\u003cstrong\u003eKey Advantages\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Xu68dMLJlo967lxsUKIcodnmnrc\"\u003e\u003cstrong\u003eSerpentine Flow-Field Design\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-AIsQdtM6po3MxIxtkREcHs5Jned\"\u003e•Extends reactant residence time within the reaction zone\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-NSYpdzOVDoFRjaxCB1kcavMnnjb\"\u003e•Enhances gas–solid–liquid interfacial contact\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-D84pd645QoiRjwxgtrGc00w0nPn\"\u003e•Commonly used in MEA and fuel-cell architectures for proven performance\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-QJnydiD1ToFsurxdDlacPOO7n4c\"\u003e\u003cstrong\u003eMulti-Electrode Configuration\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-BuRqdVwefow4Ywxpte4c4xsRnQg\"\u003e•Supports \u003cstrong\u003eWorking (WE), Counter (CE), and Reference (RE)\u003c\/strong\u003e electrodes\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-HKoQdTziOoPiiDxIxfAc8aSWn9b\"\u003e•Standard configuration includes \u003cstrong\u003eAg\/AgCl reference electrode port\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-CJf1dcDrdo9Yefx2hMTc59hynbg\"\u003e•Compatible with platinum wire, mesh, or custom counter electrodes\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-B2IPdLrZaowJ3Gx8RPXcQJDmnDd\"\u003e\u003cstrong\u003eOptimized Mass Transport\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-AncGdmASgoOxnYxagK7cENwLnKc\"\u003e•Controlled electrolyte and gas flow paths minimize dead zones\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Uiq0dyI9Nokg56xSU9tc0Gh6nbb\"\u003e•Suitable for high-current-density operation and kinetic studies\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Pqufd7J4vozlxWxzkwnc4EBqnn1\"\u003e\u003cstrong\u003eModular \u0026amp; Reconfigurable\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-FlPNdVig1oVxmJxu8SGcFWsEnsd\"\u003e•Individual layers can be disassembled for cleaning or replacement\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-XGwydFyUAo0SdmxmJ7vc26Jgn8d\"\u003e•Supports membranes, gas diffusion layers, and optical windows\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-OeCzdVg9loI01LxoRZncKaBEntd\"\u003e•Easy adaptation to different experimental schemes\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-JGISd2qZLoNsBLxoN9McyMdBnib\"\u003e\u003cstrong\u003eResearch-Grade Materials\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-NeUwdpDieoAeNjxu6OCchKj6nrd\"\u003e•Chemically resistant, mechanically stable construction\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-LCUIdmWIioDfeIxKBO6cQivInSb\"\u003e•Designed for long-term reproducibility and repeated use\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-GLnBdNNYioGYOGxfiRkcwjfcnPf\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-UPOSdV2PLoIPGfxiJakc14rcn9b\"\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-EUx2dfHMCoiSjfxZ8LlcvvIjnwe\"\u003e•Gas diffusion electrochemistry (GDE systems)\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-H65adG1w2oUlJCxQNU0c8FQynWc\"\u003e•CO₂ reduction reaction (CO₂RR)\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-JGmvdJoGGovdFyx1dKTcQpRIn4g\"\u003e•Photoelectrochemical catalysis and light-assisted reactions\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-XJE6dth06oU56JxCeTbcSntmnZd\"\u003e•Electrocatalyst screening under controlled flow conditions\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-PaiQddcmZoQdy4xZgMEca61lnnc\"\u003e•Membrane-separated electrolysis experiments\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-GmpEdzaqKow2rTxyB05cdjdXnXd\"\u003e•Fundamental studies of mass transport and reaction kinetics\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-EAbDdMauVoyeCwx9ew1ckFcrnEe\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-SoYkd0DWVoy8e7x5T5Icjy5wnyb\"\u003e\u003cstrong\u003eCell Structure \u0026amp; Working Principle\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-L25mdTgwHoKqKgxq7k8cQs96nqb\"\u003eThe Serpentine-Chamber Flow Cell consists of:\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Hvsjd3SNZo8si8xWpNDca8sSnDh\"\u003e\n\u003cstrong\u003e1.Reaction Plate with Serpentine \u003c\/strong\u003e\u003cstrong\u003eChannel\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Oa64dINNEor0QGxriRtcAcWanyc\"\u003e•Guides gas or electrolyte across the electrode surface in a controlled path\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-QYlfd5TCxoI0Ovx0uLicnVygneJ\"\u003e\n\u003cstrong\u003e2.\u003c\/strong\u003e\u003cstrong\u003eElectrode\u003c\/strong\u003e\u003cstrong\u003e Interface Layer\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-IYIJdGfwxoRQZ4x4M4jcH8X1nlc\"\u003e•Accommodates gas diffusion electrodes, metal foils, or porous electrodes\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-KrxWdf1bToJSYdxwfoqca31xncc\"\u003e\u003cstrong\u003e3.Electrolyte Chamber\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-LaHudf8glo74avx8j3Dc6X5enhI\"\u003e•Allows continuous electrolyte circulation with defined inlet\/outlet ports\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-FElOd0iEaoltHKxIslCc7s8WnJg\"\u003e\n\u003cstrong\u003e4.\u003c\/strong\u003e\u003cstrong\u003eElectrode\u003c\/strong\u003e\u003cstrong\u003e Ports\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-TTCEdihIwoODBtxd57ScGqMLnih\"\u003e•Dedicated access for WE, CE, and RE positioning close to the reaction interface\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-LHPKdMIH4omDPpxxAMUcRX8unze\"\u003eThis architecture ensures stable electrochemical performance while allowing real-time adjustment of flow rate, electrode spacing, and reaction environment.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-LLBbd3i67ovqB9xgGJpcPsRkntd\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-JXuidohaYojLfqx85PKctXBdnCb\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv data-type=\"sheet\" class=\"old-record-id-EGghd7bWUoInnmx3BJNc6xE0npe\"\u003e\n\u003cmeta http-equiv=\"Content-Type\" content=\"text\/html; charset=utf-8\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"195\"\u003e \u003ccol width=\"220\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eItem\u003c\/td\u003e\n\u003ctd\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eCell Type\u003c\/td\u003e\n\u003ctd\u003eSerpentine-Chamber Flow Cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eFlow-Field Design\u003c\/td\u003e\n\u003ctd\u003eSerpentine channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eElectrode Configuration\u003c\/td\u003e\n\u003ctd\u003eThree-electrode (WE \/ CE \/ RE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eReference Electrode\u003c\/td\u003e\n\u003ctd\u003eAg\/AgCl (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"46\"\u003e\n\u003ctd\u003eWorking Electrode\u003c\/td\u003e\n\u003ctd\u003eGas diffusion electrode, metal foil, or porous electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"46\"\u003e\n\u003ctd\u003eCounter Electrode\u003c\/td\u003e\n\u003ctd\u003ePt wire \/ Pt mesh \/ custom porous electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eFlow Mode\u003c\/td\u003e\n\u003ctd\u003eContinuous electrolyte or gas flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eTubing Interface\u003c\/td\u003e\n\u003ctd\u003eStandard laboratory fittings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eAssembly\u003c\/td\u003e\n\u003ctd\u003eModular, screw-sealed structure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003eAmbient laboratory conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"46\"\u003e\n\u003ctd\u003eCustomization\u003c\/td\u003e\n\u003ctd\u003eChannel geometry, materials, electrode size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-ZdYKdwTh0ogQjixHXhwcjJ8BnEe\"\u003e\u003cstrong\u003eMaterial Options\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-LBwLdIuOVo6r0QxVKumcXRoBnyc\"\u003eDepending on experimental requirements, the cell can be supplied with different structural materials:\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-HwLlduPqXod4mox3CbFcdBLDnUc\"\u003e•\u003cstrong\u003eHigh-purity \u003c\/strong\u003e\u003cstrong\u003etitanium\u003c\/strong\u003e – for aggressive electrochemical environments and high conductivity\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-TjP3d8PGOoZdg5x82eAcDlmXnmb\"\u003e•\u003cstrong\u003ePEEK \/ \u003c\/strong\u003e\u003cstrong\u003ePTFE\u003c\/strong\u003e – for excellent chemical resistance and electrical insulation\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-HRGWdYAEvoCFE2xvcNOcwxXNn6e\"\u003e•\u003cstrong\u003eOptical-grade windows (optional)\u003c\/strong\u003e – for photoelectrochemical observation and illumination\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-IgyVdJnemouGHVxGaKvcRzYunch\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-B1pWdRdmvoo2VGxtYNFcwI7Gn0g\"\u003e\n\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003cstrong\u003e \u0026amp; Integration\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-WiQndkfXJoawJexHQAwc4B0vnCb\"\u003e•Compatible with \u003cstrong\u003estandard potentiostats and electrochemical workstations\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-JBXodz7cAoCHcrxAaQIcAJCbnyd\"\u003e•Suitable for coupling with \u003cstrong\u003egas humidifiers, mass-flow controllers, and light sources\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-JTyQdMiqMoMjJ0xs2tJce2Bgnuh\"\u003e•Interfaces easily with CO₂, N₂, H₂, or mixed-gas supply systems\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-BYjwdwFK4oRgPjxNjQVcoSAQnyd\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-SjN1dbJrMo75jox6Y6QchqE0nID\"\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-NeiHdcxhRofSFXxOMhKcNZ1InDb\"\u003e•Serpentine-Chamber Flow Cell body\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Na0XdF7SPoNgA1xO3U7cQNvinRe\"\u003e•Reaction plate with serpentine flow field\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-QnvYdzgpOoHjnRxkmracnF29nBg\"\u003e•Electrode ports and fittings\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-O405dI0a0o2Dn8xFSdzctyUwnUt\"\u003e•Sealing gaskets and fasteners\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-SUOgdXSYuoIKaRxIN83ciTyLnkh\"\u003e•Standard Ag\/AgCl reference electrode port\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-NGeNdBVQCorFugxdT9RcINl9nxd\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-TWt7dDpJNo3a0sx91YjcT9WXngf\"\u003e\u003cstrong\u003eCustom Development\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Y06VdHkEcof3LXxg4oZcOlu5nKh\"\u003eChannel dimensions, electrode area, material selection, and port layout can be \u003cstrong\u003ecustomized\u003c\/strong\u003e to support specific research objectives, including high-current CO₂RR, photoelectrocatalysis, or scale-up feasibility studies.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-XZtTdoZocoap3pxWiGdcLuVlnwc\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-ElskdPCTsouMnXx1n1oc7bJonOb\"\u003e\n\u003cstrong\u003eSerpentine-Chamber Flow Cell\u003c\/strong\u003e \u003cem\u003eA \u003c\/em\u003e\u003cem\u003eprecision\u003c\/em\u003e\u003cem\u003e platform for advanced gas diffusion and flow-controlled electrochemical research.\u003c\/em\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eFor Custom Orders or Inquiries\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eIf you have custom requirements or any additional questions, feel free to contact us:\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cb\u003eEmail\u003c\/b\u003e: support@franklab.shop\u003c\/p\u003e","brand":"Franklab","offers":[{"title":"Serpentine-Chamber","offer_id":44634833682466,"sku":null,"price":2890.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0825\/7008\/4386\/files\/dc58f411f7d24568b8cd27eab899aec3preview.jpeg_tplv-a9rns2rl98-downsize_watermark_1_5_b.png?v=1766473406","url":"https:\/\/franklab.shop\/products\/serpentine-chamber-flow-cell","provider":"Franklab","version":"1.0","type":"link"}