Corrtest Single-Channel Potentiostat/Galvanostat with EIS Function

Regular price $14,100.00
Sale price $14,100.00 Regular price $15,819.95
Unit price
Tax included.
Compare Ask a question

Ask a Question

* Required fields

Size guide Share
  • Estimated Delivery:Jun 13 - Jun 17

  • Worldwide Free Shipping: On all orders over $499

Guarantee safe & secure checkout

Corrtest Single-Channel Potentiostat/Galvanostat with EIS Function

Corrtest Single-Channel Potentiostat/Galvanostat with EIS Function

Regular price $14,100.00
Sale price $14,100.00 Regular price $15,819.95
Unit price
Product Description
Shipping & Delivery

Single-Channel Potentiostat/Galvanostat with EIS Function

Franklab offers a high-performance Single-Channel Potentiostat/Galvanostat with EIS capability. The system integrates a DDS arbitrary function generator, potentiostat / galvanostat, and a frequency response analyzer (FRA). Equipped with dual 24-bit Delta-Sigma A/D converters, it delivers exceptional stability along with high-resolution measurements—down to 1 µV for potential and 1 pA for current.

Featuring over 40 electrochemical techniques, this device is widely used in corrosion studies, energy research, materials science, and analytical electrochemistry. Additionally, with the use of a current booster, the device can extend its output current up to ±20A, ±40A, or ±100A, and supports a higher compliance voltage of up to ±30V.

Applications:

  • Energy materials (Li-ion battery, solar cell, fuel cell, supercapacitors, etc);
  • Reactive mechanisms of electrosynthesis, electrodeposition (electroplating), anodic oxidation, electrolysis;
  • Metallic corrosion; corrosion inhibitor, coating and cathodic protection efficiency;
  • Electrocatalysis (HER, OER, ORR, CO2RR, NRR, water splitting).

Technical Specifications:

Support 2-, 3-, or 4-electrode system
Potential control range ±10V
Current control range ±2A
Potential control accuracy 0.1% × full range ±1mV
Current control accuracy 0.1% × full range
Potential resolution 10µV (>100Hz), 3µV (<10Hz)
Current sensitivity 1pA
Rise time <1µs (<10mA), <10µs (<2A)
Reference electrode input impedance 10¹²Ω || 20pF
Current range 2nA–2A, 10 ranges
Compliance voltage ±30V
Maximum current output ±2A
CV and LSV scan rate 0.001mV–10,000V/s
CA and CC pulse width 0.0001–65,000s
Current increment during scan 1mA @1A/ms
Potential increment during scan 0.076mV @1V/ms
SWV frequency 0.001–100kHz
DPV and NPV pulse width 0.0001–1000s
AD data acquisition 16bit @1MHz, 20bit @1kHz
DA Resolution 16bit, setup time: 1µs
Minimum potential increment in CV 0.075mV
IMP frequency 10µHz–1MHz
Low-pass filters Covering 8-decade
Operating System Windows 10/11
Interface USB 2.0
Weight / Dimensions 6.5kg, 36 × 30 × 16 cm
Power 90–240V AC 50/60Hz
EIS (Electrochemical Impedance Spectroscopy)
Signal Generator
Parameter Value
Frequency range 10µHz–1MHz
AC amplitude 1mV–2500mV
DC Bias -10V to +10V
Output impedance 50Ω
Waveform Sine wave, triangular wave, square wave
Wave distortion <1%
Scanning mode Logarithmic/linear, increase/decrease
Signal Analyzer
Integral time Minimum: 10ms or the longest time of a cycle
Maximum time 10⁶ cycles or 10⁵s
Measurement delay 0~105s
DC offset compensation
Potential automatic compensation range -10V to +10V
Current compensation range -1A to +1A
Bandwidth 8-decade frequency range, automatic and manual setting


Implemented Electrochemical Techniques

Stable Polarization

  • Open Circuit Potential (OCP)

  • Potentiostatic (I-T curve)

  • Galvanostatic

  • Potentiodynamic (Tafel plot)

  • Galvanodynamic (DGP)

Transient Polarization

  • Multi Potential Steps

  • Multi Current Steps

  • Potential Stair-Step (VSTEP)

  • Galvanic Stair-Step (ISTEP)

Chrono Methods

  • Chronopotentiometry (CP)

  • Chronoamperometry (CA)

  • Chronocoulometry (CC)

Voltammetry

  • Linear Sweep Voltammetry (LSV)

  • Cyclic Voltammetry (CV)

  • Staircase Voltammetry (SCV)

  • Square Wave Voltammetry (SWV)

  • Differential Pulse Voltammetry (DPV)

  • Normal Pulse Voltammetry (NPV)

  • Differential Normal Pulse Voltammetry (DNPV)

  • Alternating Current Voltammetry (ACV)

  • 2nd Harmonic AC Voltammetry (SHACV)

  • Fourier Transform AC Voltammetry (FTACV)

Electrochemical Impedance Spectroscopy (EIS)

  • Potentiostatic EIS (Nyquist, Bode)

  • Galvanostatic EIS

  • Mott–Schottky Analysis

  • Potentiostatic/ Galvanostatic EIS (Optional Frequencies)

  • EIS vs. Time (Single Frequency)

Corrosion Analysis

  • Cyclic Polarization Curve (CPP)

  • Linear Polarization Curve (LPR)

  • Electrochemical Potentiokinetic Reactivation (EPR)

  • Electrochemical Noise (EN)

  • Zero Resistance Ammeter (ZRA)

Battery Testing

  • Battery Charge and Discharge

  • Galvanostatic Charge/Discharge (GCD)

  • Potentiostatic Charging and Discharging (PCD)

  • Intermittent Titration Techniques (PITT, GITT)

Amperometry

  • Differential Pulse Amperometry (DPA)

  • Double Differential Pulse Amperometry (DDPA)

  • Triple Pulse Amperometry (TPA)

  • Integrated Pulse Amperometric Detection (IPAD)

Stripping Voltammetry

  • Potentiostatic Stripping

  • Linear Stripping

  • Staircase Stripping

  • Square Wave Stripping

  • Differential Pulse Stripping

  • Normal Pulse Stripping

  • Differential Normal Pulse Stripping

Extensions

  • Data Logger

  • Electrochemical Stripping/Deposition

  • Bulk Electrolysis with Coulometry (BE)

  • Rs Measurement

Franklab offers a wide range of electrochemical potentiostat/galvanostat systems. Please contact us for selecting the right model for your application.

FrankLab offers worldwide shipping.Orders are normally shipped from our facility in Hangzhou, China within 1-2 business days after the payment is made. It is very important that the correct shipping address is entered at checkout. We are not responsible for incorrect or undeliverable addresses.

 

Shipping Fees

Orders below USD 499 : Shipping fee of USD 14.90

Orders USD 499 and above: Free worldwide shipping

 

Large Orders & Bulk Discounts

For orders over USD 3,000, please contact our customer support team to check special pricing or potential bulk discounts before placing your order.

IMPORTANT: All goods must be inspected immediately upon delivery. Any shipping damage, missing items, or product defects must be reported to both Franklab team and the shipping carrier within 24 hours of delivery. Failure to report issues within this timeframe may result in your claim being denied. Please retain all original packaging materials, as they may be required for filing a damage claim. 

Contact Us

For shipping, returns, or bulk order inquiries, please contact:
support@franklab.shop

Discover more in our FAQ

How long does it take for me to receive my order?

What is your returns policy?

How can I place an order?

Do you charge sales tax?

Recently Viewed Products